SICOM6800ÃæÏò¹¤¿ØÇå¾²ÒªÇó½Ï¸ß³¡ºÏÑÐÖÆµÄ¹ú²ú×ÔÖ÷¿É¿Ø¶þ²ãÍø¹ÜÐÍÒÔÌ«Íø½»Á÷»ú£¬£¬£¬£¬£¬£¬½ÓÄÉ×ÔÖ÷¿É¿Ø½»Á÷оƬ¡£¡£¡£¡£¡£¡£¡£Ö§³Ö4¸öǧÕ×ÉÏÐÐ1000Base-X SFP½Ó¿ÚºÍ8¸öǧÕ×µç¿Ú¡£¡£¡£¡£¡£¡£¡£SICOM6800Ö§³ÖDT-RingÐÒé×å(×ÔÓúʱ¼ä<50ms)£¬£¬£¬£¬£¬£¬DRP/DHP£¨×ÔÓúʱ¼ä<20ms£©£¬£¬£¬£¬£¬£¬STP/RSTP/MSTP£¬£¬£¬£¬£¬£¬VLAN£¬£¬£¬£¬£¬£¬×é²¥£¬£¬£¬£¬£¬£¬QoS£¬£¬£¬£¬£¬£¬SSHµÈ¸»ºñµÄ¶þ²ãÈí¼þÌØÕ÷£¬£¬£¬£¬£¬£¬Ö§³Ö¾²Ì¬Â·ÓÉÈý²ã¹¦Ð§¡£¡£¡£¡£¡£¡£¡£Í¬Ê±Ö§³Ö»ùÓÚÓ²¼þµÄIEEE1588 PTPv2¶Ôʱ£¬£¬£¬£¬£¬£¬¶Ôʱ¾«¶È¿É´ï±100ns£¬£¬£¬£¬£¬£¬Ö§³ÖDDM¹â¹¦Âʼì²âµÄ¹¦Ð§£¬£¬£¬£¬£¬£¬²¢Ö§³ÖCLI¡¢ Telnet¡¢Web¶àÖÖ¹ÜÀí·½·¨ÒÔ¼°»ùÓÚSNMPv1/v2c/v3µÄÍø¹ÜÈí¼þ¡£¡£¡£¡£¡£¡£¡£SICOM6800¾ßÓÐIP40·À»¤µÄ½ðÊôÍâ¿Ç£¬£¬£¬£¬£¬£¬¿¹Ç¿Õñ¶¯µÄ¿¨¹ì×ù£¬£¬£¬£¬£¬£¬¼«¶ËÇéÐÎζÈ˳ӦÄÜÁ¦¼°ÓÅÒìµÄEMCµç´Å¼æÈÝÐÔÄÜ£¬£¬£¬£¬£¬£¬Ê¹¸ÃϵÁвúÆ·¾ß±¸ÔÚ±°ÁÓ¹¤ÒµÇéÐÎÏÂÎȹ̿ɿ¿ÊÂÇéµÄÄÜÁ¦¡£¡£¡£¡£¡£¡£¡£²úÆ·¿ÉÆÕ±éÓ¦ÓÃÓÚ¹¤³§×Ô¶¯»¯£¬£¬£¬£¬£¬£¬½»Í¨£¬£¬£¬£¬£¬£¬Ê¯ÓÍʯ»¯£¬£¬£¬£¬£¬£¬·çµç£¬£¬£¬£¬£¬£¬ÅäÍøµÈ¹¤ÒµÁìÓò¡£¡£¡£¡£¡£¡£¡£
Ö§³Ö4¸ö1000Base-X SFP½Ó¿Ú£¬£¬£¬£¬£¬£¬8¸öǧÕ×µç¿Ú
Ö§³Ö»ùÓÚÓ²¼þµÄIEEE1588 PTPv2£¬£¬£¬£¬£¬£¬¶Ôʱ¾«¶È ±100 ns
Ö§³ÖÈßÓàÐÒ飺DT-Ring(×ÔÓúʱ¼ä<50ms)£¬£¬£¬£¬£¬£¬DRP/DHP£¨×ÔÓúʱ¼ä<20ms£©£¬£¬£¬£¬£¬£¬STP/RSTP/MSTP
Ö§³ÖÇå¾²ÊÖÒÕ£ºHTTPS/SSL£¬£¬£¬£¬£¬£¬SSH£¬£¬£¬£¬£¬£¬TACACS+£¬£¬£¬£¬£¬£¬IEEE802.1X£¬£¬£¬£¬£¬£¬RADIUS£¬£¬£¬£¬£¬£¬Óû§·Ö¼¶£¬£¬£¬£¬£¬£¬¶Ë¿Ú¸ôÀë
Ö§³ÖCLI¡¢Telnet¡¢Web¶àÖÖ¹ÜÀí·½·¨ÒÔ¼°»ùÓÚSNMPv1/v2c/v3µÄÍø¹ÜÈí¼þ
Ö§³ÖDDM¹â¹¦Âʼì²â¹¦Ð§
IP40·À»¤Æ·¼¶£¬£¬£¬£¬£¬£¬-40~75¡æÊÂÇéζÈ
| Èí¼þ¹¦Ð§ | |
| ½»Á÷¹¦Ð§ | Ö§³ÖVLAN , PVLAN Ö§³ÖGVRP Ö§³Ö¶Ë¿Ú¾ÛºÏ, LACP Ö§³Ö¶Ë¿ÚÁ÷¿Ø Ö§³Ö¶Ë¿ÚÏÞËÙ Ö§³Ö¶Ë¿Ú·ç±©ÒÖÖÆ |
| ÈßÓàÊÖÒÕ | Ö§³ÖDT-Ring, DT-Ring+, DT-VLANÐÒé×壬£¬£¬£¬£¬£¬×ÔÓúʱ¼ä<50ms Ö§³ÖDRP/DHP,×ÔÓúʱ¼ä<20ms Ö§³ÖSTP/RSTP/MSTP Ö§³ÖMRP Ö§³ÖERPS |
| ×é²¥ÊÖÒÕ | Ö§³ÖIGMP Snooping Ö§³ÖGMRP Ö§³Ö¾²Ì¬×é²¥ |
| Çå¾²ÊÖÒÕ | Ö§³ÖHTTPS/SSL Ö§³ÖSSH Ö§³ÖTACACS+ Ö§³ÖIEEE802.1X Ö§³ÖRADIUS Ö§³ÖÓû§·Ö¼¶ Ö§³Ö¶Ë¿Ú¸ôÀë Ö§³ÖIP Source Guard |
| ·þÎñÖÊÁ¿¹ÜÀí | Ö§³ÖQoS, 802.1p(CoS), DSCP Ö§³ÖSP, WRRÐÐÁе÷Àí Ö§³ÖACL |
| ¹¤ÒµÐÒé | Ö§³ÖEtherNet/IP Ö§³ÖModbus/TCP |
| ¹ÜÀíÓëά»¤ | Ö§³ÖConsole, Telnet, WEB¹ÜÀí·½·¨ Ö§³ÖSNMPv1/v2c/v3£¬£¬£¬£¬£¬£¬¿Éͨ¹ýKyvision¼¯ÖйÜÀí Ö§³ÖFTP/TFTP/HTTP/HTTPS·½·¨Èí¼þÉý¼¶ Ö§³ÖFTP/TFTP/HTTP/HTTPS·½·¨ÉèÖÃÎļþÉÏ´«ÏÂÔØ Ö§³ÖµçÔ´¸æ¾¯, IP/MAC³åÍ»¸æ¾¯, ÄÚ´æ/CPUʹÓÃÂʸ澯, ¶Ë¿Ú¸æ¾¯, »·¸æ¾¯, ¶Ë¿ÚÁ÷Á¿¸æ¾¯, CRC¼°¶ª°üÂʸ澯, SFP½Ó¿ÚÎüÊչ⹦Âʸ澯ºÍ·¢Ë͹⹦Âʸ澯 Ö§³ÖDDM (SFP½Ó¿Ú) Ö§³Ö»·Â·¼ì²â Ö§³ÖRMON Ö§³Ö¶Ë¿Ú¾µÏñ Ö§³ÖSyslog Ö§³ÖLLDP Ö§³ÖLink-check Ö§³ÖIPv4/IPv6 |
| IP¹ÜÀí | Ö§³ÖDHCP server/snooping/client/relay, DHCP Option 82 Ö§³ÖDNS Ö§³ÖARP |
| ʱÖÓ¹ÜÀí | Ö§³ÖIEEE 1588 PTPv2 Ö§³ÖIEEE 802.1AS gPTP Ö§³ÖSNTP Client & Server Ö§³ÖNTP Client & Server Ö§³ÖÊ±ÇøºÍÏÄÁîʱÉèÖà |
| ·ÓÉ | Ö§³Ö¾²Ì¬Â·ÓÉ |
| ²úÆ·¹æ¸ñ | |
| ÊÖÒÕ²ÎÊý | ±ê×¼ IEEE 802.3i (10Base-T) IEEE 802.3u (100Base-T and 100Base-FX) IEEE 802.3ab (1000Base-T) IEEE 802.3z (1000Base-SX/LX) IEEE 802.3ad (Á´Â·¾ÛºÏ) IEEE 802.3x (Á÷¿Ø) IEEE 802.1p (ÓÅÏȼ¶) IEEE 802.1Q (VLAN) IEEE 802.1d (STP) IEEE 802.1w (RSTP) IEEE 802.1s (MSTP) IEEE 802.1x (Network Access Control) IEEE 802.1ab (LLDP) IEEE1588 (PTP) IEEE 802.1AS (gPTP) IEEE 802.1CB |
| ½»Á÷ÊôÐÔ | ÓÅÏȼ¶ÐÐÁÐ 8 VLANÊý 4094 VLAN ID 1¡«4093 ×é²¥×éÊý 1K IPv4·ÓÉ 128 ARP±í512 MAC±í 16K °ü»º³åÇø 6Mbit °üת·¢ÂÊ 17.9Mpps ½»Á÷ÑÓ³Ù <10¦Ìs ³¬³¤Ö¡³¤¶È 10K bytes ½»Á÷ÈÝÁ¿ 24Gbps |
| ½Ó¿Ú | ǧÕ×¶Ë¿Ú 1000Base-X, 10/100/1000Base-T(X) SFP½Ó¿Ú 10/100/1000Base-T(X), RJ45½Ó¿Ú Console¿Ú RS232,RJ45½Ó¿Ú ¸æ¾¯¶Ë¿Ú 7о5.08mm¼ä¾à²åÈëʽ¶Ë×Ó,250VAC/220VDC Max, 2A Max |
| ָʾµÆ | Ç°Ãæ°åָʾµÆ ÔËÐÐָʾµÆ:Run ¸æ¾¯Ö¸Ê¾µÆ:Alarm µçԴָʾµÆ:PWR1,PWR2 ½Ó¿ÚָʾµÆ:Link/ACT, Speed(µç¿Ú); Link/ACT(¹â¿Ú) |
| °´Å¥ | Reset:Ö§³ÖÖØÆôºÍ»Ö¸´Ä¬ÈÏÉèÖà |
| µçÔ´ | ÊäÈëµçѹ 12-48VDC ½ÓÈë¶Ë×Ó 7о5.08mm¼ä¾à²åÈëʽ¶Ë×Ó ¹¦ÂÊ <18W ¹ýÔØ±£»£»£»£»£»¤ Ö§³Ö ·´½Ó±£»£»£»£»£»¤ Ö§³Ö ÈßÓà±£»£»£»£»£»¤ Ö§³Ö |
| »úе½á¹¹ | Íâ¿Ç ½ðÊô²ÄÖÊ É¢ÈÈ·½·¨ ×ÔÈ»ÀäÈ´,ÎÞµçÉÈ ·À»¤Æ·¼¶ IP40 ³ß´ç 53mm¡Á135mm¡Á108mm (W¡ÁH¡ÁD) ÖØÁ¿ 0.8Kg ×°Ö÷½·¨ DIN¿¨¹ìʽ»ò±Ú¹Òʽ |
| ÇéÐÎ | ÊÂÇéÎÂ¶È -40¡æ¡«+75¡æ Öü´æÎÂ¶È -40¡æ¡«+85¡æ Ïà¶Ôʪ¶È 5¡«95%ÎÞÄý¶ |
| Öʱ£ | ±£ÐÞÆÚ 5Äê |
| ÈÏÖ¤ | CE, FCC EMC: EN 55032/35, EN 61000-6-4, EN 61000-6-2 |
| ÐÐÒµ±ê×¼ | EMI FCC CFR47 Part 15,EN55032/CISPR22,Class A EMS IEC61000-4-2(ESD) ¡À6kV(contact),¡À8kV(air) IEC61000-4-3(RS) 10V/m(80MHz¡«2GHz) IEC61000-4-4(EFT) Power Port:¡À2kV;Data Port:¡À1kV IEC61000-4-5(Surge) Power Port:¡À1kV/DM,¡À2kV/CM;Data Port:¡À2kV IEC61000-4-6(CS) 10V(150kHz¡«80MHz) »úе IEC60068-2-6(Õñ¶¯) IEC60068-2-27(¹¥»÷) IEC60068-2-32(×ÔÓɵøÂä) |

²úÆ·Ñ¡ÐÍ
|
²úÆ·ÐͺŠ|
Êä³ö½Ó¿Ú |
µçÔ´ |
|
SICOM6800-L2-4GX8GE-LV-LV |
4×1000Base-X, 10/100/1000Base-T(X) SFP½Ó¿Ú; 8×10/100/1000Base-T(X) RJ45 µç¿Ú |
12-48VDC£¬£¬£¬£¬£¬£¬ÈßÓàÊäÈë |
Ñ¡¹ºÅä¼þ
|
Åä¼þÐͺŠ|
Åä¼þ˵Ã÷ |
|
SFPÄ£¿£¿£¿£¿£¿£¿£¿é |
²Î¿¼¹¤Òµ¼¶SFPÄ£¿£¿£¿£¿£¿£¿£¿éÑ¡¹º±í |
|
DT-BGAZ-02 |
±Ú¹Ò×°Öð壬£¬£¬£¬£¬£¬±àÂ룺109020050 |
|
DT-FCZ-RJ45-01 |
µ¥¿ÚRJ45·À³¾ÕÖ£¬£¬£¬£¬£¬£¬±àÂ룺109999005 |
|
RJ45/DB9-2M |
´®¿ÚÍø¹ÜÏߣ¬£¬£¬£¬£¬£¬RJ45/DB9£¬£¬£¬£¬£¬£¬2Ã×£¬£¬£¬£¬£¬£¬±àÂ룺111030019 |